PLA Cream Adhesive Remover - Large
Regular price $20.00PLA Cream adhesive remover designed to help safely dissolve adhesive bonds in professional eyelash extensions without damaging the natural lash. Cream removers are gentle on the eyes and very effective in softening cyanoacrylate.
Cream remover has a shelf life of 6 months opened, as long as it does not dry out.
NET 10g
Directions:
- Avoid contact with skin.
- Apply with micro-swab.
- Allow cream remover to sit on lashes for ten minutes.
- Easily remove lashes by “sandwiching” between two eyepads, or remove with tweezers.
- Wipe clean with a cotton swab and wash away any residue.
- Rinse before reapplying new lash extensions.
For more information, please watch this video.
Warning: this product is intended for professional use only.
Liquid products, including adhesive, primers, bonders, and cream based products cannot be returned.
MSDS
MSDS |MATERIAL SAFETY DATA SHEET
Section 1 – Chemical Product and Company Identification
MSDS NAME |
Cream Adhesive Remover |
COMPANY ADDRESS |
825 Maestro Drive Reno, NV 89521, USA Tel:775-440-1208
|
|
|
Section 2 – Composition and Ingredient Information
Ingredient Component Name
Squalane (Vegetable)
CAS Number 111-01-3
Phenoxyethanol
CAS 122-99-6
Hydroxypropyl Methylcellulose
CAS Number 9004-65-3
Bentonite
CAS Number 1302-78-9
Propylene carbonate
CAS Number 108-32-7
Ethoxydiglycol
CAS Number 111-90-0
Sorbian Isostearate
CAS Number 71902-01-7
Vitis Vinfera (Grape) Oil
CAS Number 8016-21-5
Section 3 – Hazards Identification
Hazard Risk Classification
|
Category 1 |
Potential Health Effect |
Eye: May cause eye irritation
Skin: May cause skin irritation Inhalation: May cause respiratory tract irritation. The toxicological properties of this substance have not been fully investigated
Ingestion: May cause digestive tract disturbances. The toxicological properties of this substance have not been fully investigated. May be harmful if swallowed.
|
|
Chronic: No information found
|
For additional information on toxicity, please refer to section 11 |
Section 4 – First Aid Measures
Inhalation |
If inhaled, remove to fresh air. If not breathing give artificial respiration. If breathing is difficult, give oxygen
|
Eye Contact |
In case of contact, immediately flush eyes with large amounts of water for at least 15 minutes.
|
Skin Contact |
In case of unexpected irritation, immediately wash skin with soap and large amounts of water
|
Ingestion |
If swallowed, wash out mouth with water provided person is conscious. Call a physician
|
|
|
Section 5 – Fire Fighting Measures
Specific Hazard |
N/A |
Flash Point |
N/A
|
Auto Ignition temperature |
N/A
|
Flammable/Explosive Limits-lower% |
Not determined
|
Flammable/Explosive Limits-upper% |
Not determined
|
Hazardous Decomposition Materials |
N/A
|
Suitable Extinguishing Media |
For small fires, use products such as alcohol foam, dry chemical, or carbon dioxide . |
Protective Equipment |
For large fires, apply water from as far as possible. Use very large quantities of water as a mist or spray of water may be ineffective. Cool all affected containers with large quantities of water.
|
Hazardous combustion products |
Trace amount of toxic and or irritating fumes may be released and the use of breathing apparatus is recommended.
|
Unusual fire or explosion hazard |
None
|
Specific Hazard(s) |
Combustible liquid. Emits toxic fumes under fire conditions. |
Section 6 – Accidental Release Measures
General Information |
Use proper personal protective equipment as listed in section 10
|
Environmental precautions |
Spills and leaks absorb spill with inert material (e.g. vermiculite, sand or earth), then place in suitable container. Clean
|
Disposal and Clean Up |
Clean up spills immediately, observing precautions in the Protective Equipment section. Provide ventilation. |
Section 7 – Handling and Storage
Handling Precautions |
Keep away from heat, sparks and flame. Wash thoroughly after handling
|
Storage |
Keep container closed when not in use. Store in a cool, dry, well-ventilated area away from incompatible substances. Keep containers tightly closed
|
Section 8 – Exposure Controls and Personal Protection
Engineering Controls |
N/A |
Respiratory Protection |
N/A |
Skin Protection |
N/A |
Eye/Face protection |
N/A |
General Hygiene measures |
Wash contaminated clothing before reuse. Wash thoroughly after handling
|
Section 9 – Physical and Chemical Properties
Physical State |
Pink cream/pastes |
Odour |
None |
pH |
Not available |
Specific Gravity |
Not available |
Boiling Point |
Not available |
Flash Point |
Not available |
Flammability |
Not available |
Evaporation Rate(Ether=1) |
N/A |
Ignition Temperature |
Not available |
Melting/Freezing Point |
Not available |
Solubility |
Soluble in Water |
Vapour Density |
Not available |
Vapour Pressure |
Not available |
Volatile Organic Compound(EPA Method24) |
Not available |
Section 10 – Stability and Reactivity
Stability |
Stable under normal temperatures and pressures
|
Conditions to Avoid |
None listed
|
Incompatible Materials |
None listed
|
Hazardous Polymerization |
None listed
|
Hazardous decomposition |
None listed
|
Section 11– Toxicological Information
Toxicity: Skin contact may cause irritation but not allergenic effect.Routes of Entry: Inhalation (Yes), Skin (Yes) , ingestion (No) Carcinogen etc: See No. 3
|
Section 12– Ecological Information
No data available
Section 13– Disposal Consideration
No data available
Section 14– Transport
INTERNATIONAL AIR TRANSPORT ASSOCIATION (IATA) :This product is not classified as dangerous goods, by rules of IATA.U.S Department of transportation (DOT) Shipping regulations: This product is not classified as dangerous goods, per U.S. DOT regulation under 49CFR 172.101.Proper shipping name: PRIME 6 (glue for false eyelashes)Hazard Class number and description: Not applicable identification number: Not applicable. Packing group: Not applicable
Section 15– Regulatory Information
CA Proportion 65: No California proposition 65 chemicals are known to be present.
Section 16– Other Information
To the best of knowledge, the information contained herein is accurate. However, neither our company nor any subsidiaries assumes any liability whatsoever for the accuracy or completeness of the information contained herein. All materials may present unknown.